ANALISIS KINERJA HEAT EXCHANGER PADA PREHEATER CDU V DI KILANG RU V BALIKPAPAN

Ibnu Eka Rahayu, Siti Nur Izzah, Muhammad Rahadian Hidayat

Abstract


Separation of crude oil in a petroleum processing plant requires a tool for heat exchanger. Heat Exchanger is used to transfer heat between two or more fluids that have a temperature difference, ranging from a high-temperature fluid to a low-temperature fluid. This process at PT. PERTAMINA RU V Balikpapan is located in the Crude Distillation Unit V (CDU V). The part of the heat exchanger that serves as preheating of petroleum is E-201-01A / B to E-201-11 or commonly referred as a pre-heater circuit. The important role of the pre-heater in the Crude Distillation Unit (CDU V) is significant in order to evaluate the performance of the heat exchanger so that it can be used as a basis for carrying out the cleaning process if it is found when its performance has decreased. Performance evaluation is conducted by comparing the Dirt Factor / Fouling factor (Rd) of the design data and the actual data obtained. The results obtained were heat exchanger E-201-04A / B, E-201-05A / B, E-201-06, E-201-08A / B, E-201-09, E-201-10A / B, and the E-201-11 had the actual Rd value higher than the design Rd, which indicated that there had been a decrease in performance on the heat exchanger. Heat exchanger E-201-04A / B, E-201-05A / B, E-201-06, E-201-08A / B, E-201-09, E-201-10A / B, E-201- 11 had the actual Rd value lower than the design Rd which indicated that the heat exchanger was still performing well. Heat exchangers that have a higher Actual Rd value than RD design are recommended to carry out immediate cleaning according to the conditions of the tool.

Keywords


heat exchanger; preheater; Rd value; crude oil; CDU V

Full Text:

PDF

References


Cengel, Y.A. (2006). Heat Transfer: A Practical Approach (2nd Ed). Ohio: McGraw- Hill Higher Education.

Donald Q. Kern. 1965. Process Heat Transfer, edisi internasional, McGraw Hill, New York.

Hardjono, A., Teknologi Minyak Bumi, Gadjah Mada University Press, 2000.

Holman, JP. Alih bahasa E.Jasifi. “Perpindahan Kalor”. Penerbit Erlangga. Jakarta. 1995. Incropera FP, Dewitt DP. Fundamental of Heat and Mass Transfer .4th Ed.New York: J. Wiley; 1996. International (P) Ltd

Incropera, DW, Heat and Mass Transfer,Mc.Graw Hill Book Company,NY, 1987.

Incropera, F.P and De Witt D.P,Fundamentals of Heat and Mass Transfer,Third Edition, John Wiley & Sons, 1990.

J. P. Holman, HEAT TRANSFER, sixth Edition. Erlangga, Jakarta. 1994.

Kakac, S., Liu, H. (2002). Heat exchanger: Selection, Rating, and Thermal Design (2nd Ed). Florida: CRC Press.

Kothandaraman, C.P. (2006). Fundamentals of Heat and Mass Trasfer (3rd Ed). New Delhi: New Age Kreith, F, Prinsip Perpindahan Panas,Erlangga, Jakarta, 1986.

Max Jacob & George A. Hawkins, Purdue Univerity, ”Elements Of Heat Transfer”, Jhon Wiley & sons.inc, edisi 3,Th 1957.

Sitompul,Tunggul,M. ”Alat Penukar Kalor” ,PT. Raja Grafindo Persada, Jakarta, 1991.




DOI: https://doi.org/10.46964/jimsi.v1i1.614

Refbacks

  • There are currently no refbacks.


Copyright (c) 2021 Jurnal Teknik Kimia Vokasional

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

 

  

 

 

 


Editor Jurnal Teknik Kimia Vokasional (JIMSI) address :

ISSN 2775-9083 (Print) | ISSN 2775-9075 (Online)

Department Of Chemical Engineering, Politeknik Negeri Samarinda
Jl. Dr. Ciptomangunkusumo Kampus Gunung Panjang Samarinda 75131
Phone: Zainal Arifin (+62 857 500 60 400) 
E-Mail: jimsi@polnes.ac.id

 

Creative Commons License
Jurnal Teknik Kimia Vokasional (JIMSI) by http://e-journal.polnes.ac.id/index.php/jimsi is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

503 Service Unavailable

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Additionally, a 503 Service Unavailable error was encountered while trying to use an ErrorDocument to handle the request.

503 Service Unavailable

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Additionally, a 503 Service Unavailable error was encountered while trying to use an ErrorDocument to handle the request.